Các lỗi thường gặp

Code :
  • Code: SC425
  • Description: Potential sensor error 6: Vl adjustment M
    Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Drum worn • LD unit dirty • Poor drum ground connection
  • Code: SC426
  • Description: Potential sensor error 7: Vl adjustment C
    Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Drum worn • LD unit dirty • Poor drum ground connection
  • Code: SC427
  • Description: Potential sensor error 8: Vl adjustment Y
    Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Drum worn • LD unit dirty • Poor drum ground connection
  • Code: SC432
  • Description: Potential sensor error 1: Vr K
    Vr > 200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
  • Causes: • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
  • Code: SC433
  • Description: Potential sensor error 2: Vr M
    Vr > 200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
  • Causes: • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
  • Code: SC434
  • Description: Potential sensor error 3: Vr C
    Vr > 200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
  • Causes: • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
  • Code: SC435
  • Description: Potential sensor error 4: Vr Y
    Vr > 200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
  • Causes: • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective
  • Code: SC436
  • Description: Potential sensor error: Vd K
    The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -800)
  • Causes: • Potential sensor dirty • Potential sensor defective • Charge roller defective • Charge power pack defective • OPC defective