Description: TD sensor (Vt high) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt high) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt high) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt high) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt low) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt low) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt low) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt low) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin