Các lỗi thường gặp

Code :
  • Code: SC360
  • Description: TD sensor (Vt high) error: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC361
  • Description: TD sensor (Vt high) error: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC362
  • Description: TD sensor (Vt high) error: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC363
  • Description: TD sensor (Vt high) error: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC364
  • Description: TD sensor (Vt low) error: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC365
  • Description: TD sensor (Vt low) error: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC366
  • Description: TD sensor (Vt low) error: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC367
  • Description: TD sensor (Vt low) error: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.