Description: Developer Fill Error: K
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Code: SC351
Description: Developer Fill Error: M
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Code: SC352
Description: Developer Fill Error: C
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Code: SC353
Description: Developer Fill Error: Y
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Code: SC356
Description: Toner Supply Error 1: K
The machine detected 10 times that the amount of toner applied to create the black ID sensor pattern on the drum between sheets (SP3101-1 ID Pattern Display - Applied K) was less than the minimum threshold setting (0.0 mg/cm2). Also, the total time for the operation of the sub hopper clutch (SP3251-1 Tnr Supply Time - Sub Hopper CL: K) exceeded the threshold of 65K ms.
Causes: • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
Code: SC357
Description: Toner Supply Error 2: M
The machine detected 10 times that the amount of toner applied to create the magenta ID sensor pattern on the drum between sheets (SP3101-2 ID Pattern Display - Applied M) was less than the minimum threshold setting (0.0 mg/cm2). Also, the total time for the operation of the sub hopper clutch (SP3251-2 Tnr Supply Time - Sub Hopper CL: M) exceeded the threshold of 65K ms.
Causes: • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
Code: SC358
Description: Toner Supply Error 3: C The machine detected 10 times that the amount of toner applied to create the cyan ID sensor pattern on the drum between sheets (SP3101-3 ID Pattern Display - Applied C) was less than the minimum threshold setting (0.0 mg/cm2). Also, the total time for the operation of the sub hopper clutch (SP3251-3 Tnr Supply Time - Sub Hopper CL: C) exceeded the threshold of 65K ms.
Causes: • Toner end sensor cleaning spring broken, mechanism defective • Toner end sensor loose, broken, or defective • Replace toner supply unit
Code: SC359
Description: Toner Supply Error 4: Y
The machine detected 10 times that the amount of toner applied to create the yellow ID sensor pattern on the drum between sheets (SP3101-4 ID Pattern Display - Applied Y) was less than the minimum threshold setting (0.0 mg/cm2). Also, the total time for the operation of the sub hopper clutch (SP3251-4 Tnr Supply Time - Sub Hopper CL: Y) exceeded the threshold of 65K ms.