Description: Development gamma calculation error: Insufficient data (Y). The number of valid data that can be used for development gamma calculation is smaller than 2.
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
Code: SC402-61
Description: Development gamma calculation error: LD unlit (K). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Code: SC402-62
Description: Development gamma calculation error: LD unlit (C). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Code: SC402-63
Description: Development gamma calculation error: LD unlit (M). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Code: SC402-64
Description: Development gamma calculation error: LD unlit (Y). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Code: SC403-01
Description: Development Start Voltage (Vk) High Error (K). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
Causes: • Toner density error
Remedy: • Replace the developer.
Code: SC403-02
Description: Development Start Voltage (Vk) High Error (C). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
Causes: • Toner density error
Remedy: • Replace the developer.
Code: SC403-03
Description: Development Start Voltage (Vk) High Error (M). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].