Description: Development gamma calculation error: Insufficient data (Y). The number of valid data that can be used for development gamma calculation is smaller than 2.
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
Description: Development gamma calculation error: LD unlit (K). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Description: Development gamma calculation error: LD unlit (C). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Description: Development gamma calculation error: LD unlit (M). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Description: Development gamma calculation error: LD unlit (Y). Unable to draw gradation pattern Details: This SC is issued when the potential sensor fails to detect the gradation pattern created during process control.
Causes: • LD unlit
Remedy: • Check the LD system and electric components.
Description: Development Start Voltage (Vk) High Error (K). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
Description: Development Start Voltage (Vk) High Error (C). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
Description: Development Start Voltage (Vk) High Error (M). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
Causes: • Toner density error
Remedy: • Replace the developer.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.