Các lỗi thường gặp

Code :
  • Code: SC403-04
  • Description: Development Start Voltage (Vk) High Error (Y). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
  • Causes: • Toner density error
  • Remedy: • Replace the developer.
  • Code: SC404-01
  • Description: Development Start Voltage (Vk) Low Error (K). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
  • Code: SC404-02
  • Description: Development Start Voltage (Vk) Low Error (C). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
  • Code: SC404-03
  • Description: Development Start Voltage (Vk) Low Error (M). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
  • Code: SC404-04
  • Description: Residual Voltage (Vr) Detection Error (K). Development Start Voltage (Vk) Low Error (Y). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
  • Code: SC410-01
  • Description: Residual Voltage (Vr) > 200[-V] Details: This SC is issued when the residual voltage measured duringprocess control exceeded 200 [-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
  • Code: SC410-02
  • Description: Residual Voltage (Vr) Detection Error (C). Residual Voltage (Vr) > 200[-V] Details: This SC is issued when the residual voltage measured duringprocess control exceeded 200 [-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
  • Code: SC410-03
  • Description: Residual Voltage (Vr) Detection Error (M). Residual Voltage (Vr) > 200[-V] Details: This SC is issued when the residual voltage measured duringprocess control exceeded 200 [-V].
  • Causes: • Toner density error • Condensation
  • Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.