Description: PCB fan error: Folder Unit The machine detected a continuous lock signal from the PCB cooling fan on the PSU for 20 sec.
Causes: • Fan harness connector loose, disconnected, broken • Overload on the fan motor due to physical obstruction such has undetected paper, etc. • Fan defective • MCU folder unit defective
Remedy:
Code: 819
Description: Fatal kernel error Due to a control error, a RAM overflow occurred during system processing.
Remedy: For more details about this SC code error, execute SP5990 to print an SMC report so that you can read the error code. The error code is not displayed on the operation panel.
Code: 820
Description: Self-Diagnostic Error: CPU The CPU returned an unexpected error during the self-diagnostic test.
Description: Self-diagnostic error 2: ASIC The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate.
Causes: • Controller board defective
Remedy: For more details about this SC code error, execute SP5990 to print an SMC report so that you can read the error code. The error code is not displayed on the operation panel.
Code: 822
Description: Self-diagnostic error 3: HDD An error occurred when the self-check was performed when the machine was switched on after the HDD was replaced. (The diagnostic command was issued to the HDD device but the result was an error).