Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPW5100 — Trang 8/15

Code: SC636

Description: Expansion recognition module error GW An error has occurred while trying to access the file of the expansion recognition module.
Causes: • DESS module does not exist on SD card • External expansion recognition module does not exist on SD card • SD card damaged • External expansion recognition file corrupted
Remedy:

Code: SC641

Description: Engine-to-controller communication error: No response GW The controller sent a frame to the main machine engine but there was no response as demanded by RAPI protocol. The frame was sent 3 times at 100 ms intervals. This SC was issued after the 3rd attempt failed.
Causes: • Examine the connection between the controller and the engine board. • Replace the engine board if the error is frequent.
Remedy:

Code: SC650

Description: Cumin-M communication error GW An error occurred with the Cumin modem (dialup, modem port) when the machine was switched on.
Causes: • The settings for @Remote SP5816 are incorrect • Modem disconnected from the phone line • Modem port disconnected • Wireless LAN card missing
Remedy:

Code: SC651

Description: @Remote dial-up incorrect
Causes: An unexpected error occurred while the machine was dialing up the @Remove service center via modem.
Remedy:

Code: SC670

Description: Engine startup error GW The BCU failed to respond with the prescribed time when the machine was turned on.
Causes: • Connections between BCU and controller board are loose, disconnected, or damaged • Replace the BCU • Replace the controller board
Remedy:

Code: SC671

Description: Illegal engine board detected GW An illegal engine board was detected at power on by the firmware.
Causes: • NIA
Remedy:

Code: SC672

Description: Controller startup error GW After power on, the line between the controller and the operation panel did not open for normal operation. After normal startup, communication with the controller stopped.
Causes: • Controller stalled • Controller installed incorrectly • Controller board defective • Operation panel harness disconnected or defective
Remedy:

Code: SC687

Description: Per-command error The main machine received no per-command module from the GW controller.
Causes: • Poor communication, cycle the machine power off/on
Remedy: