Code: 490-009

Description: IITB black lift motor error The machine detects a short or open signal of the coil in the ITB black motor.
Causes: • ITB drawer incorrectly set • Harness from IOB 2 to this motor short, broken or disconnected • Coil in this motor short or open
Remedy: 1. Check if the ITB drawer is correctly set. 2. Check the harness connection. 3. Replace the harness. 4. Replace the ITB black lift motor.

Code: 490-010

Description: ITB color lift motor error The machine detects a short or open signal of the coil in the ITB color motor.
Causes: • ITB drawer incorrectly set • Harness from IOB 2 to this motor short, broken or disconnected • Coil in this motor short or open
Remedy: 1. Check if the ITB drawer is correctly set. 2. Check the harness connection. 3. Replace the harness. 4. Replace the ITB color lift motor.

Code: 490-011

Description: Belt centering motor error The machine detects a short or open signal of the coil in the belt centering motor.
Causes: • ITB drawer incorrectly set • Harness from IOB 2 to this motor short, broken or disconnected • Coil in this motor short or open
Remedy: 1. Check if the ITB drawer is correctly set. 2. Check the harness connection. 3. Replace the harness. 4. Replace the belt centering motor.

Code: 490-012

Description: ITB drive motor error The machine detects a short or open signal of the coil in the ITB drive motor.
Causes: • ITB drawer incorrectly set • Harness from IOB 2 to this motor short, broken or disconnected • Coil in this motor short or open
Remedy: 1. Check if the ITB drawer is correctly set. 2. Check the harness connection. 3. Replace the harness. 4. Replace the ITB drive motor.

Code: 490-013

Description: PTR lift motor error The machine detects a short or open signal of the coil in the PTR lift motor.
Causes: • ITB drawer incorrectly set • Harness from RCB to this motor short, broken or disconnected • Coil in this motor short or open
Remedy: 1. Check the harness connection. 2. Replace the harness. 3. Replace the PTR lift motor.

Code: 492

Description: TD sensor K error • The TD sensor for a color determines that no developer is in the development unit at TD sensor initialization. • The TD sensor for a color does not detect a normal output from the development unit during printing.
Causes: • No developer in the development unit • Agitation auger defective
Remedy: 1. Check or reinstall developer in the development unit. 2. Replace the development unit.

Code: 493

Description: TD sensor C error • The TD sensor for a color determines that no developer is in the development unit at TD sensor initialization. • The TD sensor for a color does not detect a normal output from the development unit during printing.
Causes: • No developer in the development unit • Agitation auger defective
Remedy: 1. Check or reinstall developer in the development unit. 2. Replace the development unit.

Code: 494

Description: TD sensor M error • The TD sensor for a color determines that no developer is in the development unit at TD sensor initialization. • The TD sensor for a color does not detect a normal output from the development unit during printing.
Causes: • No developer in the development unit • Agitation auger defective
Remedy: 1. Check or reinstall developer in the development unit. 2. Replace the development unit.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie