Mã lỗi Ricoh Aficio Pro C720S — Trang 50/85

Code: 775

Description: Jogger Top Fence Motor: 3K Finisher B830 The top fence HP sensor detected that: The top fence did not arrive at the home position within the specified number of pulses. -or- The top fence failed to leave the home position within the specified number of pulses.
Causes: If the jogger top fence motor is operating: • Top fence HP sensor harness loose, broken, defective • Top fence HP sensor defective If the jogger top fence motor is not operating: • Motor blocked by an obstruction • Motor harness loose, broken, defective • Motor defective • Finisher main board defective
Remedy: 1. Check or clear obstacles around the motor drive mechanism. 2. Check the harness connection. 3. Replace the top fence HP sensor. 4. Replace the top fence motor. 5. Replace the finisher main board.

Code: 776

Description: Jogger Bottom Fence Motor: 3K Finisher B830 The bottom fence HP sensor detected that: The bottom fence did not arrive at the home position at the specified time. -or- The bottom fence failed to leave the home position at the specified time.
Causes: If the jogger bottom fence motor is operating: 1. Bottom fence HP sensor harness loose, broken, defective 2. Bottom fence HP sensor defective If the jogger bottom fence motor is not operating: 1. Motor blocked by an obstruction 2. Motor harness loose, broken, defective 3. Motor defective 4. Finisher main board defective
Remedy: 1. Check or clear obstacles around the motor drive mechanism. 2. Check the harness connection. 3. Replace the top fence HP sensor. 4. Replace the top fence motor. 5. Replace the finisher main board.

Code: 780

Description: Z-Fold Feed Motor Error The feed motor that drives the feed rollers and exit rollers in the Z-fold unit is not operating. The 1st alert signals a jam, the 2nd alert triggers this SC.
Causes: • Motor harness loose, broken, defective • Motor blocked by an obstruction • Motor defective
Remedy: 1. Check or clear obstacles around the motor drive mechanism. 2. Check the harness connection. 3. Replace the feed motor.

Code: 781

Description: Z-Fold Lower Stopper Motor Error The lower stopper failed to leave the home position with the specified number of motor pulses. • The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
Causes: • Lower stopper motor disconnected, defective • Lower stopper motor overloaded due to obstruction • Lower stopper HP sensor disconnected, defective
Remedy: 1. Check or clear obstacles around the motor drive mechanism. 2. Check the harness connection. 3. Replace the lower stopper motor.

Code: 782

Description: Z-fold Upper Stopper Motor The upper stopper failed to leave the home position with the specified number of motor pulses. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
Causes: • Upper stopper motor disconnected, defective • Upper stopper motor overloaded due to obstruction • Upper stopper HP sensor disconnected, defective
Remedy: 1. Check or clear obstacles around the motor drive mechanism. 2. Check the harness connection. 3. Replace the upper stopper motor.

Code: 784

Description: Z-Fold Timing Sensor Adjustment Error 1 The output voltage light emitted from the sensor changed, but the return input was not sufficient to attain V0.
Causes: • Sensor, mirror dirty from paper dust, other particles • Harness loose, broken, defective • Mirror out of position
Remedy: 1. Check the harness connection. 2. Replace the fold timing sensor.

Code: 785

Description: Z-Fold Timing Sensor Adjustment Error 2 The output voltage light emitted from the sensor changed, but the return input was not sufficient to attain V0.
Causes: • Sensor, mirror dirty from paper dust, other particles • Harness loose, broken, defective • Mirror out of position
Remedy: 1. Check the harness connection. 2. Replace the leading edge sensor.

Code: 786

Description: Z-Fold Memory Error Several attempts to write to the Z-fold memory failed.
Causes: • Turn the machine power off/on • EEPROM on Z-Folder main board defective
Remedy: 1. Check the harness connection. 2. Replace the main board.