Description: ID sensor error: Development Y. Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Remedy: 1. Replace the ID/ MUSIC sensors. 2. Check the harness connection to the LD unit. 3. Replace the LD unit. 4. Check the harness connection to the CGB HVPS. 5. Replace the CGB HVPS. 6. Replace the developer.
Description: ID sensor error: Development start voltage K • The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (±150V)
Remedy: 1. Replace the ID/ MUSIC sensors. 2. Check the harness connection to the LD unit. 3. Replace the LD unit. 4. Check the harness connection to the CGB HVPS. 5. Replace the CGB HVPS. 6. Replace the developer.
Description: ID sensor error: Development start voltage C • The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (±150V)
Remedy: 1. Replace the ID/ MUSIC sensors. 2. Check the harness connection to the LD unit. 3. Replace the LD unit. 4. Check the harness connection to the CGB HVPS. 5. Replace the CGB HVPS. 6. Replace the developer.
Description: ID sensor error: Development start voltage M • The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (±150V)
Remedy: 1. Replace the ID/ MUSIC sensors. 2. Check the harness connection to the LD unit. 3. Replace the LD unit. 4. Check the harness connection to the CGB HVPS. 5. Replace the CGB HVPS. 6. Replace the developer.
Description: ID sensor error: Development start voltage Y • The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (±150V)
Remedy: 1. Replace the ID/ MUSIC sensors. 2. Check the harness connection to the LD unit. 3. Replace the LD unit. 4. Check the harness connection to the CGB HVPS. 5. Replace the CGB HVPS. 6. Replace the developer.
Description: Potential sensor error: Vd Adjustment K. The drum potential sensor detects 150V or more on the drum (Vd) for 0.7 msec. when the high voltage charge is supplied to the drum for the initial sampling before exposure.
Description: Potential sensor error: Vd Adjustment C. The drum potential sensor detects 150V or more on the drum (Vd) for 0.7 msec. when the high voltage charge is supplied to the drum for the initial sampling before exposure.