Description: Potential sensor error 3: Vr adjustment M Vr < –200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is less than –200V.
Description: Potential sensor error 4: Vr adjustment Y Vr < –200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is less than –200V.
Description: Potential sensor error: Vd adjustment K The Vd Home reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -900)
Description: Potential sensor error: Vd adjustment C The Vd Home reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -900)
Description: Potential sensor error: Vd adjustment M The Vd Home reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -900)
Description: Potential sensor error: Vd adjustment Y The Vd Home reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -900)
Description: Image transfer HVPS error: K An interrupt checks the status of the HVPS every 10 ms. This SC is issued if the BCU detects a short in the HVPS for K, M, C, or Y.
Causes: • Transfer HVPS cable disconnected or damaged • Transfer HVPS defective
Remedy: 1. Check the cables or cable connections of the transfer HVPS. 2. Replace the transfer HVPS.
Description: Image transfer HVPS error: C An interrupt checks the status of the HVPS every 10 ms. This SC is issued if the BCU detects a short in the HVPS for K, M, C, or Y.
Causes: • Transfer HVPS cable disconnected or damaged • Transfer HVPS defective
Remedy: 1. Check the cables or cable connections of the transfer HVPS. 2. Replace the transfer HVPS.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.