Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio SP3410DN — Trang 2/3

Code: 541

Description: Fuser thermistor error
The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
Causes: • Disconnected or defective thermistor • Disconnected or defective fusing lamp 1. Check the harness connection of the thermistor. 2. Replace the fusing unit. • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.

Code: 542

Description: Fuser reload error
This SC is issued if one of following conditions occurs: The fusing temperature rises 8°C or less in 1.5 seconds; and this continues 5 times consecutively. -or- The fusing temperature has not reached 45°C within 9 seconds (after the fusing lamp comes ON while the machine is warming-up). -or- The fusing unit does not attain reload temperature within 35 s. (normal temperature) or 65 s (lower temperature – the thermistor output is less than 18°C) after the fusing temperature control starts.
Causes: • Defective or deformed thermistor • Incorrect power supply input at the main power socket 1. Defective fusing lamp

Code: 543

Description: High temperature error (Software)
• The detected temperature stays at 225°C for 1 second, and this consecutively occurs 10 times.
Causes: • Defective ECB • Defective PSU 1. Replace the ECB 2. Replace the PSUt unit. • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.

Code: 544

Description: High temperature error (Hardware)
• During stand-by mode or a print job, the detected heating roller temperature reaches 250° C.
Causes: • Defective ECB • Defective PSU 1. Replace the ECB 2. Replace the PSU • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.

Code: 545

Description: Fusing Lamp Overheat Error
The fusing lamps remained ON at full capacity for more than 9 s after the fusing temperature attains reload temperature.
Causes: • Deformed thermistor • Thermistor not in the correct position • Defective fusing lamp 1. Replace the fusing unit. 2. Replace the fusing lamp. • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.

Code: 547

Description: Zero cross error
• The zero cross signal is detected three times even though the fusing lamp relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the fusing lamp relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45. • The zero cross signal is not detected three times while the main power remains ON.
Causes: • Defective fusing relay • Defective fusing relay circuit • Shorted +24V fuse on the PSU • Unstable power supply. 1. Check the power supply source. 2. Replace the +24V fuse on the PSU. 3. Replace the PSU

Code: 557

Description: Zero cross frequency error
The zero cross signal is detected ten times while the fusing lamp relay remains ON after turning on the main power.
Causes: • Defective fusing lamp relay • Defective drive circuit of the fusing lamp relay • Unstable input power source 1. Check the power supply source. 2. Replace the fusing unit. • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.

Code: 559

Description: Fuser 3times jam error
The paper jam counter for the fusing unit reaches 3. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when this function is enabled with "Engine Maintenance" (default "OFF").
Causes: • Defective fusing unit • Defective fusing control 1. Clear this SC to send a command after a jam removal. 2. Turn off this function after a jam removal. • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie