Description: Self-diagnostic error 7: ROM
Measuring the CRC for the boot monitor and operating system program results in an error. A check of the CRC value for ROMFS of the entire ROM area results in an error.
Causes: Software defective. Controller board defective. ROM defective
Code: 829
Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test.
Causes: Replace the optional memory board. Controller board defective
Code: 833, 834
Description: For more details about SC 833, SC834 error.
Execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel. The additional error codes (0F30, 0F31, etc. are listed in the SMC report).
Causes:
Code: 838
Description: Self-diagnostic Error: Clock Generator
A verify error occurred when setting data was read from the clock generator via the I2C bus.
Causes: Replace the controller board
Code: 851
Description: IEEE 1394 I/F error
Driver setting incorrect and cannot be used by the 1394 I/F.
Causes: NIB (PHY), LINK module defective; change the Interface Board. Controller board defective
Code: 853
Description: Wireless LAN Error 1
During machine start-up, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card (802.11b or Bluetooth).