Description: Paper tray unit communication error
Three consecutive errors occur during polling, after the paper tray unit is successful I2C communication.
Description: Counter device error 1
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device. 1. Check if the setting of the SP5113 is correctly set. 2. Check the connection between the main machine and optional counter device.
Description: Counter device error 2
After communication is established, the controller receives the brake signal from the accounting device.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device. 1. Check if the setting of the SP5113 is correctly set. 2. Check the connection between the main machine and optional counter device.