Description: BICU/Finisher communication/break error During communication with the finisher MBX, the BICU received a break (Low) signal from the finisher.o
Causes: • Serial line connection unstable • External noise on the line
Description: BICU/Tray 1-4 communication/timeout error After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable • External noise on the line
Description: BICU/LCT communication/timeout error After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable • External noise on the line
Description: NRS Modem Communication Error One of the following factors could be the cause of this error: • Modem has been disconnected. • Modem board disconnected.
Causes: Check the following for a machine that is using Cumin (NRS modem): • An error was returned during the dialup connection • A network was detected at startup • At startup the machine detected that the NIB was disabled, or did not detect a modem board