Code: 599

Description: 1-bin Exit Motor Error (Japan Only)
The transport lock sensor output does not change within 300 ms after the motor switches on.
Causes: • Motor overload • Motor driver defective

Code: 621

Description: BICU/Finisher communication/break error
During communication with the finisher MBX, the BICU received a break (Low) signal from the finisher.o
Causes: • Serial line connection unstable • External noise on the line

Code: 623

Description: BICU/Tray 1-4 communication/timeout error
After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable • External noise on the line

Code: 624

Description: BICU/Tray 1-4 communication/break reception error
During communication with the finisher trays, the BICU received a break (Low) signal.
Causes: • Serial line connection unstable • External noise on the line

Code: 626

Description: BICU/LCT communication/timeout error
After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable • External noise on the line

Code: 627

Description: BICU/LCT communication/break reception error
During communication with the LCT, the BICU received a break (Low) signal.
Causes: • Serial line connection unstable • External noise on the line

Code: 650

Description: NRS Modem Communication Error
One of the following factors could be the cause of this error: • Modem has been disconnected. • Modem board disconnected.
Causes: Check the following for a machine that is using Cumin (NRS modem): • An error was returned during the dialup connection • A network was detected at startup • At startup the machine detected that the NIB was disabled, or did not detect a modem board

Code: 651

Description: Illegal Remote Service Dial-up
An expected error occurred when Cumin- M dialed up the NRS Center.
Causes: • Software bug • No action is required because only the count is logged