Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio SPC440DN — Trang 8/16

Code: 520

Description: 2nd paper tray cooling fan error (optional paper feed unit). The motor lock signal error from the cooling fan is detected for 10 seconds after turning on the cooling fan.
Causes: • Disconnected harness of the cooling fan • Defective cooling fan • Defective BCU
Remedy: 1. Check or replace the harness of the cooling fan. 2. Replace the cooling fan. 3. Replace the BCU.

Code: 521

Description: 3rd paper tray cooling fan error (optional paper feed unit). The motor lock signal error from the cooling fan is detected for 10 seconds after turning on the cooling fan.
Causes: • Disconnected harness of the cooling fan • Defective cooling fan • Defective BCU
Remedy: 1. Check or replace the harness of the cooling fan. 2. Replace the cooling fan. 3. Replace the BCU.

Code: 522

Description: 4th paper tray cooling fan error (optional paper feed unit). The motor lock signal error from the cooling fan is detected for 10 seconds after turning on the cooling fan.
Causes: • Disconnected harness of the cooling fan • Defective cooling fan • Defective BCU
Remedy: 1. Check or replace the harness of the cooling fan. 2. Replace the cooling fan. 3. Replace the BCU.

Code: 530

Description: Development fan 1 error. The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective development fan 1 or development fan 2 • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the development fan 1 (SC530) or development fan 2 (SC531). 3. Replace the BCU.

Code: 531

Description: Development fan 2 error. The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective development fan 1 or development fan 2 • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the development fan 1 (SC530) or development fan 2 (SC531). 3. Replace the BCU.

Code: 532

Description: Laser unit fan error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective laser unit fan • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the laser unit fan. 3. Replace the BCU.

Code: 533

Description: Fusing fan 2 error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective fusing fan 2 • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the fusing fan 2. 3. Replace the BCU.

Code: 534

Description: Fusing fan 1 error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective fusing fan 1 • Disconnected or defective harness • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the fusing fan 1. 3. Replace the BCU.