Mã lỗi Ricoh Aficio SPC811DN — Trang 11/23
Code:
Tất cả lỗi (179)
195
202
203
204
210
211
212
213
220
221
222
223
224
225
226
227
230
231
232
233
234
235
236
237
240
241
242
243
285
290
291
292
293
294
295
296
300
301
302
303
360
361
362
363
364
365
366
367
372
373
374
375
380
396
397
398
399
400
441
442
443
452
460
490
491
492
498
501
502
503-01
503-02
504-01
504-02
505-01
505-02
529
530
531
532
533
534
535
536
540
541
542
543
544
547
548
549
551
552
553
554
557
559
561
562
563
564
565
580
581
582
583
584
585
586
587
610
611
621
622
623
669
670
681
682
683
687
689
690
721
723
725
730
740
741
742
743
744
746
750
753
760
761
763
764
791
792
818
819
820
821
822
823
824
826
827
828
829
851
853
854
855, 856
857
860
861
863
864
865
866
867
868
870
872
873
874
875
876
877
900
920
921
990
991
992
998
Description: Second duct fan error The machine does not detect the fan motor lock signal for 2 seconds while the second duct fan turns on.
Causes: • Disconnected harness • Overload on the second duct fan motor • Defective second duct motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the second duct fan. 3. Replace the IOB.
Description: Paper exit fan error The machine does not detect the fan motor lock signal for 2 seconds while the paper exit fan turns on.
Causes: • Disconnected harness • Overload on the paper exit fan motor • Defective paper exit motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the paper exit fan. 3. Replace the IOB
Description: Third duct fan error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective controller fan motor
Remedy: Replace the controller fan motor.
Description: Fusing/Paper exit motor error The IOB does not receive the lock signal 10 seconds after turning on the fusing/ paper exit motor.
Causes: • Motor overload • Defective fusing/paper exit motor
Remedy: Replace the fusing/paper exit motor.
Description: Heating roller thermopile error The temperature measured by the heating roller thermopile does not reach 0°C for 6 seconds
Causes: • Loose connection of the heating roller thermopile • Defective heating roller thermopile • Defective thermopile
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the heating roller thermopile.
Description: Heating roller warm-up error 1 • The heating roller temperature does not reach the ready temperature for 190 seconds after the IH inverter turns on. • The heating roller temperature does not reach 80°C for 18 seconds after the IH inverter on.
Causes: • Dirty or defective thermopile • Defective IH coil unit
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the thermopile. 3. Replace the IH coil unit.
Description: Heating roller overheat 1 (software error) The detected fusing temperature stays at 215°C for 1 second.
Causes: • Defective PSU • Defective IOB • Defective EGB
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the EGB.
Description: Heating roller overheat 1 (hardware error) During stand-by mode or a print job, the detected heating roller temperature reaches 220 °C.
Causes: • Defective PSU • Defective IOB • Defective EGB • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the EGB.