Description: Fusing sleeve belt overheat: Center (hardware error) During stand-by mode or a print job, the detected fusing sleeve belt temperature reaches 250°C.
Causes: Defective PSU. Defective BCU. Defective AC control board. Defective IOB. Defective fusing control system.
Remedy: • Replace the PSU. • Replace the BCU. • Replace the AC controller board. • Replace the IOB. Replace the fusing unit and reset the counter of the fusing unit using SP3-902-014. Important: • The fusing unit cannot be used because an abnormal high temperature was detected. After this SC occurs, the counter reset of the fusing unit should be done manually using SP3-902-014 because the counter reset is not done automatically. • After replacing fusing unit, to set SP5-810-2 is necessary to reset this SC.
Description: Zero cross error After the zero-crossing interrupt setting is enabled, the machine waits for 50+-20 ms. If a request for zero-crossing interrupt is received while waiting, the machine retries the search after the waiting time is completed. The detection occurs consecutively 3 times.
Remedy: • Turn the main power switch off and on. • If the fusing relay is damaged, replace the PSU. • Check the connection between the PSU and control board, and then replace the harness and board if necessary.
Description: Fusing heater connection error The fusing sleeve belt rotation sensor detects the target temperature as 50°C for 5 seconds or more after the fusing/paper exit motor has turned on.
Description: Fusing sleeve belt thermistor error The temperature at the end of the fusing sleeve belt measured by the fusing sleeve belt thermistor does not reach -50°C for 0.1 seconds.
Description: Fusing sleeve belt overheat: End (software error) The detected fusing sleeve belt temperature stays at 240°C or more for 1 second for 10 consecutive times.
Causes: The triac switch has shorted out. Defective IOB. Defective BCU.
Description: Fusing sleeve belt overheat: End (hardware error) The fusing sleeve belt thermistor detects 250°C or more.
Causes: Defective PSU. Defective BCU. Defective AC control board. Defective IOB. Defective fusing control system.
Remedy: • Replace the PSU. • Replace the BCU. • Replace the AC controller board. • Replace the IOB. • Replace the fusing unit and reset the counter of the fusing unit using SP3-902-014. Important: The fusing unit cannot be used because an abnormal high temperature was detected. • After this SC occurs, the counter reset of the fusing unit should be done manually using SP3-902-014 because the counter reset is not done automatically. • After replacing fusing unit, to set SP5-810-2 is necessary to reset this SC.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.