Description: LCT lower limit error
The lower limit sensor does not activate within 8 seconds after the tray has been lowered.
Causes: • Tray lift motor defective • Poor connection of the tray lift motor • Lower limit sensor defective • Too much load on the drive mechanism
Code: 520
Description: Paper tray error
An error occurs (i.e motor error, or sensor error, etc) for any paper tray.
Causes: • A defective motor • A defective sensor • Too much load on the drive mechanism
Code: 541
Description: Fusing thermistor open
The fusing temperature detected by the thermistor was below 0 °C for 5 seconds. The fusing temperature does not rise +15 °C (center) or +12 °C (at the ends) five times within 2 minutes after the fusing lamps have been turned on.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermostat open • Power supply board defective • Poor connection of the fusing unit
Code: 542
Description: Fusing temperature warm-up error
The fusing temperature does not reach the standby temperature within 20 seconds after the main switch is turned on.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Fusing thermostat open • Power supply board defective • Poor connection of the fusing unit
Code: 543
Description: Fusing overheat error 1
A fusing temperature of over 231°C is detected for 5 second by the fusing thermistor.
Description: Fusing overheat error 3
After warmup, the hot roller attained full operating temperature and maintained this temperature for 10 sec. without the hot roller rotating.
Causes: • Hot roller thermistor is out of position • Fusing lamp broken • Thermostat broken
Code: 546
Description: Unstable fusing temperature
The fusing temperature varies 50°C or more within 1 second twice continuously.
Causes: • Thermistor defective • Poor connection of the fusing unit • Power supply unit defective