Các lỗi thường gặp

Code :
  • Code: 195
  • Description: DFGATE assert error
    The DFGATE signal does not assert within 30 seconds after the original has been scanned.
  • Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
  • Code: 196
  • Description: DFGATE negate error
    The DFGATE signal does not negate within 1 minute after the DFGATE has been asserted.
  • Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
  • Code: 197
  • Description: DFGATE error
    The DFGEATE signal has already been asserted at the original scan.
  • Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
  • Code: 198
  • Description: Memory address error
    The IPU board does not receive the memory address from the controller board.
  • Causes: • Mismatched firmware between the SBCU board and controller board • Controller defective • SBCU defective • IPU board defective
  • Code: 199
  • Description: DF scanning finish error
    The original does not finish scanning with in 1 minute
  • Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
  • Code: 302
  • Description: Charge roller current leak
    A charge roller current leak signal is detected.
  • Causes: • Charge roller damaged • Charge high voltage supply board defective • Poor connection of the PCU
  • Code: 320
  • Description: Polygon motor error
    The polygon motor does not reach its operating speed within 10 seconds after the polygon motor on signal, or the lock signal is not detected for more than 200 ms continuously during operation.
  • Causes: • Polygon mirror motor defective • Poor connection between the polygon mirror motor driver and the SBCU board • SBCU board defective
  • Code: 322
  • Description: Laser synchronization error
    The main scan synchronization detector board cannot detect the laser synchronization signal for more than 10 consecutive 50 ms intervals.
  • Causes: • Poor connection between the laser synchronization detector board and the SBCU board • Laser synchronization detector board out of position • Laser synchronization detector board defective • SBCU board defective • LD unit defective