Description: Zero cross signal malfunction
Zero cross signals are not detected within a certain period.
Causes: • Power supply board defective • SBCU board defective
Code: 548
Description: Fusing unit set error
The machine does not detect the fusing unit.
Causes: • Poor connection of the fusing unit • The fusing unit is not installed
Code: 590
Description: Exhaust fan motor error
The CPU detects an exhaust fan lock signal for more than 5 seconds.
Causes: • Poor connection of the exhaust fan motor • Too much load on the motor drive
Code: 611
Description: Communication break error between SBCU and ADF
The SBCU receives a break signal from the ADF main board.
Causes: • Serial line connecting SBCU and ADF unstable • External noise • ADF main board defective • SBCU board defective
Code: 612
Description: Communication command error between SBCU and ADF
The SBCU sends a command to the ADF main board that it cannot execute.
Causes: • SBCU board defective • Download SBCU firmware again
Code: 620
Description: Communication timeout error between SBCU and finisher
The SBCU cannot receive a response within 100 ms after 3 attempts after sending data to the finisher.
Causes: • Serial line connecting SBCU and finisher unstable • External noise • SBCU board and finisher main board connection defective or loose • Finisher main board defective • SBCU board defective
Code: 621
Description: Communication timeout error between SBCU and finisher
A break (low) signal was received from the finisher.
Causes: • Serial line connecting SBCU and finisher unstable • External noise
Code: 630
Description: Communication failure with CSS (RSS)
The communication from the copier was detected as abnormal at the CSS center. This error occurs when the acknowledge signal from the LADP does not complete normally.
Causes: • Occurred with an SC call, CC call, supply management call, user call, or CE call. • Timeout while no response from the LADP, and abnormal signal on the RS-485 line between PI and LADP.