Causes: • Unsuitable toner density • Toner supply mechanism problem • Laser exposure problem • Image transfer problem
Code: 390
Description: Development Bias output error
The high voltage supply board (C/B) checks the circuit and detects abnormal conditions such as a voltage leak or no output condition. If this happens, the high voltage supply board sends an error signal (High to Low at CN204A18) to the BCU. The BCU checks this signal every 2 ms and generates this SC code when the error condition occurs 250 consecutive times.
Causes: • Loose connection • Defective power pack C/B output • Damaged cable • Defective development unit • Defective BCU
Code: 391
Description: Charge AC: output error
391-01: K 391-02: Y 391-03: M 391-04: C The high voltage supply board sends the feedback signal (CN228-2 to 5; MCYK). The BCU checks these feedback signals every 8 ms. If the average of the sampled data is not within the control target 20 consecutive times, this SC code is generated.
Causes: • Power pack disconnected • Charge receptacle or terminal • Defective PCU bias input terminal • Incorrect power pack B/C output • Damaged cable • Defective BCU • PCU not found
Code: 392
Description: Air pump motor error
392-001: MY 392-002: CK Three consecutive errors are detected in motor-driver-signal samples. The samples are collected every 0.01 second.
Causes: • Damaged cable • Short circuit • Defective motor
Code: 393
Description: TD sensor error during warming up
393-001: K 393-002: Y 393-003: C 393-004: M The development-unit drive starts. TD sensor signal is 0.78 V or less.
Causes: • Loose cable connection • Positioning plate out of place • Defective TD sensor • Development unit not found
Code: 440
Description: Drum motor error
440-001: Black 440-002: Color No drum gear position sensor signal is detected within 0.8 second (C2a/k: 125 mm/s, C2b: 162 mm/s) or 2.0 seconds (81 mm/s).
Causes: • Defective PCU • Defective drum motor • Defective drum gear position sensor
Code: 460-001
Description: Thermistor 1 error (open circuit)
When the temperature detected by thermistor 1, which is at the left (fusing unit) side of the laser optics unit, is less than -30°C for 10 seconds consecutively, the BCU determines that the circuit is open and shows this SC code.
Description: Thermistor 1 error (short circuit)
When the temperature detected by the thermistor 1, which is at the left (fusing unit) side of the laser optics unit, is higher than 70°C for 10 seconds consecutively, the BCU determines that the circuit is shorted and shows this SC code