Các lỗi thường gặp

Code :
  • Code: 261
  • Description: LD HP sensor not switched off (for K only)
    After the laser beam pitch is changed, it takes more than five seconds for the HP sensor to switch off.
  • Causes: • Defective motor • Defective sensor • Mechanical problem when switching the actuator • Brown fuse (FU81) on the Power supply unit
  • Code: 285
  • Description: Line position adjustment (MUSIC) error
    Line position adjustment fails four consecutive times.
  • Causes: • Pattern sampling error due to insufficient image density of patterns used for the adjustment • Inconsistency in the sampling line position adjustment pattern due to dust on the pattern, damage to the OPC drum, damage or toner dropped on the transfer belt, or a dirty or defective ID sensor
  • Code: 370
  • Description: TD sensor [K]: Adjustment error
  • Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
  • Code: 371
  • Description: TD sensor [Y]: Adjustment error
  • Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
  • Code: 372
  • Description: TD sensor [C]: Adjustment error
  • Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
  • Code: 373
  • Description: TD sensor [M] : Adjustment error
  • Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
  • Code: 374
  • Description: Vt error [K]
    During the image development, Vt value is less than 0.78V.
  • Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
  • Code: 375
  • Description: Vt error [Y]
    During the image development, Vt value is less than 0.78V.
  • Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor