Description: LD HP sensor not switched off (for K only)
After the laser beam pitch is changed, it takes more than five seconds for the HP sensor to switch off.
Causes: • Defective motor • Defective sensor • Mechanical problem when switching the actuator • Brown fuse (FU81) on the Power supply unit
Code: 285
Description: Line position adjustment (MUSIC) error
Line position adjustment fails four consecutive times.
Causes: • Pattern sampling error due to insufficient image density of patterns used for the adjustment • Inconsistency in the sampling line position adjustment pattern due to dust on the pattern, damage to the OPC drum, damage or toner dropped on the transfer belt, or a dirty or defective ID sensor
Code: 370
Description: TD sensor [K]: Adjustment error
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 371
Description: TD sensor [Y]: Adjustment error
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 372
Description: TD sensor [C]: Adjustment error
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 373
Description: TD sensor [M] : Adjustment error
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 374
Description: Vt error [K]
During the image development, Vt value is less than 0.78V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Code: 375
Description: Vt error [Y]
During the image development, Vt value is less than 0.78V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor