Code: SC202

Description: Polygon Motor Error 1: ON Timeout
The polygon mirror motor did not reach its operating speed within 20 s after the polygon motor switched on.
Causes: • Connection between the polygon mirror motor control board and the motor is loose, broken, or defective
• Polygon mirror motor defective
• Polygon mirror motor control board defective
• IPU defective
• BCU defective

Code: SC203

Description: Polygon Motor Error 2: OFF Timeout
The polygon mirror motor did not go off within 3 s after the motor was switched off.
Causes: • Connection between the polygon mirror motor control board and the motor is loose, broken, or defective
• Polygon mirror motor defective
• Polygon mirror motor control board defective
• IPU defective
• BCU defective

Code: SC204

Description: Polygon Motor Error 3: XSCRDY Signal Error
The machine detected that the polygon mirror motor XSCRDY signal went inactive :
• While an image was being created
• During the output of a synchronous laser detection signal
Causes: • Switch the machine off/on (problem was probably due to electronic noise)
• Replace the harness if cycling the machine off/on does not solve the problem
• Polygon motor defective
• Polygon mirror motor control board defective
• IPU defective
• BCU defective

Code: SC205

Description: Polygon Motor Error 4: Unstable Timeout
The machine detected that the polygon mirror motor signal went inactive at some time other than: • While an image was being created • During the output of a synchronous laser detection signal
Causes: • Switch the machine off/on (problem was probably due to electronic noise)
• Replace the harness if cycling the machine off/on does not solve the problem
• Polygon motor defective
• Polygon mirror motor control board defective
• IPU defective

Code: SC220

Description: Synchronization Detector Error 1: LD0
When LD0 fired with the polygon mirror motor rotating at normal speed, an synchronous detection signal was not output within 250 ms.
Causes: • Cycle the machine off/on
• Harness connector of the laser synchronization detector board is loose, broken, defective
• Laser synchronization detection board defective or installed improperly
• LD unit defective
• IPU defective
• BCU defective

Code: SC221

Description: Synchronization Detection Error 2: Other Than LD0
When a laser diode (other than LD0) fired with the polygon mirror motor rotating at normal speed, an synchronous detection signal was not output within 250 ms.
Causes: • Cycle the machine off/on
• Harness connector of the laser synchronization detector board is loose, broken, defective
• Laser synchronization detection board defective or installed improperly
• LD unit defective
• IPU defective
• BCU defective

Code: SC230

Description: FGATE Error 1: Signal Failed to Turn On
The FGATE signal did not switch on within 1 s of when the lasers were supposed to start writing the image.
Causes: • Cycle the machine off/on
• Check the harnesses, connectors of the IPU, Controller, BCU
• GAVD on the IPU board defective
• Controller defective
• BCU defective

Code: SC231

Description: FGATE Error 2: Signal Failed to Turn Off
The FGATE signal did not switch off within 7 s of when the lasers started writing the image, or remained off at the beginning of the next job.
Causes: • Cycle the machine off/on
• Check the harnesses, connectors of the IPU, Controller, BCU
• GAVD on the IPU board defective
• Controller defective
• BCU defective