Description: Charge Corona Error 1: Charge Leak
A abnormal detection signal (H) was detected for more than 60 ms. Also, during this time, the detected voltage remained below –4V for more than 50 ms.)
Causes: • Cycle the machine off/on
• CGB power pack harness connectors loose, broken, defective
• Corona wire caps loose, missing
• CGB power pack defective
• Charge corona unit connectors loose, broken, defective
Code: SC304
Description: Charge Corona Error 2: Grid Leak
A high feedback voltage (H) for the charge corona 60 ms. Also, during this time, the voltage of the charge grid remained less than –400V
Causes: • Cycle the machine off/on
• Charge unit set incorrectly (not locked in place)
• Charge unit connector loose, broken, defective
Code: SC305
Description: Charge Corona Wire Cleaner Error 1
One of these occurred after the charge corona cleaner motor was switched on: • The charge corona wire cleaner motor remained locked within 10 sec after the motor switched on. • The charge corona wire cleaner motor failed to lock within 45 s after the start of cleaning.
Causes: • Cycle the machine off/on
• Charge corona wire cleaner motor defective
Code: SC306
Description: Charge Corona Wire Cleaner Error 2
The cleaning pad of the charge corona wire cleaner mechanism failed to return to its home position.
Causes: Connectors between motor and IOB loose, broken, defective
• Charge wire dirty, defective, broken
• Wire cleaning pad defective
• Motor or motor board in motor unit defective
Code: SC312
Description: Pre-Charge Output Error 1: Leak
An abnormal signal (H) was detected continuously for 60 ms. During this time the pre-charge unit voltage remained less than –3 kV for more than 50 ms.
Causes: • Pre-charge unit set incorrectly.
• Pre-charge unit contact is broken or defective.
Code: SC313
Description: Pre-Charge Output Error 1: Grid Output
An abnormal signal (H) was detected continuously for 60 ms. During this time the pre-charge grid voltage remained less than –400V for more than 50 ms.
Causes: • Pre-charge unit set incorrectly
• Pre-charge unit contact is broken or defective
Code: SC320
Description: Development Bias Error
An abnormal detection signal (H) was detected continuously for 60 ms. During this time the voltage exceeded –90µA for more than 50 ms
Causes: • Development power pack connectors loose, broken, defective
• Development unit connectors loose, broken, defective
• Development power pack defective