Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh B234 MP9000 B-C3 — Trang 11/25

Code: SC545

Description: Fusing Overheat Error 3: Continuous Lamp On
After warm-up and while the hot roller is not rotating, the fusing lamps remain on at full power for 45 s (B234/B235) 90 s (B236).
Causes: • Fusing thermistor out of position
• One or more fusing lamp is disconnected

Code: SC547

Description: Zero-Cross Signal Not Detected
The applied bandwidth is detected above 66 Hz or below 45 Hz, and no zero-cross signal detected for 5 s with the power relay ON.
Causes: • Noise on the ac power line
• Cycle the machine off/on
• If the problem continues, install a noise filter

Code: SC557

Description: Zero-Cross Signal Over
Noise was detected on the power supply line.
Causes: • Cycle the machine off/on
• If the problem continues, install a noise filter

Code: SC559

Description: Fusing Unit Jam Error
The paper cooling job time sensor detected paper late for 3 counts. This SC only occurs if SP1159 is on, and a jam occurred in the fusing unit for three consecutive sheets of paper.
Causes: • Remove the paper that is jammed in the fusing unit. Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.

Code: SC585

Description: Double-Feed LED Adjustment Error
The calibration of the double-feed LED for the paper type failed reach the target voltage. The print job completed without the double-feed detection operating. The target voltages are: • Normal paper 3.0V±1% • Translucent paper: 3.8V±2% • OHP: 4.0V±2%
Causes: • Double-feed sensor/LED dirty
• Sensor/LED connector loose, broken, defective

Code: SC592

Description: Toner Bank Motor Error
An abnormal signal was received from the toner bank motor.
Causes: • Toner bank motor defective
• Bank motor connector loose
• Mechanical overload on the drive mechanism

Code: SC593

Description: Toner Suction Motor Replace Alert
The total operation time of the motor exceeded 600 hours. Note: A near-end message appears on the operation panel when the service life of the motor exceeds 570 hours.
Causes: • The toner suction motor has reached the end of its service life.

Code: SC601

Description: Communication Error Between BCU and MCU
One or more of the following occurred:
• The BCU cannot communicate with the MCU within 100 ms after power on after 3 tries.
• A BREAK signal was detected after connection between the BCU and MCU.
• After a communication error, three tries to communicate with the MCU failed.
Causes: • Poor connection between BCU and MCU
• BCU defective
• MCU defective