Code :
                
                    
                
            
            
                
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-001
 
                        - Description:  Board Power Error-2 PSU-EA1 ch2: 24V power off error The machine detects 24 V power off from the PSU-EA1.
 
                        - Causes:  • Harness broken or disconnected • Interlock signal from IOB 2 detected • RB defective • PSU-EA1 defective
 - Remedy:  1. Check or replace the harness. 2. Replace the PSU-EA1. 3. Replace the RB.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-002
 
                        - Description:  Board Power Error-2 IOB 1: 24V_2AINT power off error The machine detects 24 V power off from the IOB 1.
 
                        - Causes:  • PSU-EA1 defective • FU105 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-003
 
                        - Description:  Board Power Error-2 IOB 1: 24V_2BINT power off error The machine detects 24 V power off from the IOB 1.
 
                        - Causes:  • PSU-EA1 defective • FU104 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-004
 
                        - Description:  Board Power Error-2 RCB: 24V_2BINT power off error The machine detects 24 V power off from the RCB.
 
                        - Causes:  • PSU-EA1 defective • IOB 1 defective • Registration unit disconnected
 - Remedy:  1. Check the registration unit connection. 2. Replace the IOB 1. 3. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-005
 
                        - Description:  Board Power Error-2 IOB 1: 24VINT power off error The machine detects 24 V power off from the IOB 1.
 
                        - Causes:  • PSU-EA1 defective
 - Remedy:  Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-006
 
                        - Description:  Board Power Error-2 IOB 1: 24VINTA power off error The machine detects 24 V power off from the IOB 1.
 
                        - Causes:  • PSU-EA1 defective • IOB 1 defective • FU104 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-007
 
                        - Description:  Board Power Error-2 RCB: 24VINTA1 power off error The machine detects 24 V power off from the RCB.
 
                        - Causes:  • Registration unit disconnected • PSU-EA1 defective • IOB 1 defective
 - Remedy:  1. Check the registration unit connection. 2. Replace the IOB 1. 3. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-008
 
                        - Description:  Board Power Error-2 RCB: 24VINTA2 power off error The machine detects 24 V power off from the RCB.
 
                        - Causes:  • Registration unit disconnected • PSU-EA1 defective • IOB 1 defective
 - Remedy:  1. Check the registration unit connection. 2. Replace the IOB 1. 3. Check or replace the PSU-EA1.