Code :
                
                    
                
            
            
                
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-009
 
                        - Description:  Board Power Error-2 IOB 2: 24VINT power off error The machine detects 24 V power off from the IOB 2.
 
                        - Causes:  • PSU-EA1 defective
 - Remedy:  Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               675-010
 
                        - Description:  Board Power Error-2 IOB 2: 24VINTA The machine detects 24 V power off from the IOB 2.
 
                        - Causes:  • PSU-EA1 defective • FU101 on the IOB 2 shorted or opened
 - Remedy:  1. Replace the IOB 2. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               676-001
 
                        - Description:  Board Power Error-3 PSU-EA1: 24V_ch3 power off error The machine detects 24 V power off from the PSU-EA1.
 
                        - Causes:  • Harness broken or disconnected • PSU-EA1 defective
 - Remedy:  1. Check or replace the harness. 2. Replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               676-002
 
                        - Description:  Board Power Error-3 IOB 2: 24V_3A power off error The machine detects 24 V power off from the IOB 2.
 
                        - Causes:  • PSU-EA1 defective • FU103 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               676-003
 
                        - Description:  Board Power Error-3 IOB 2: 24V_3B power off error The machine detects 24 V power off from the IOB 2.
 
                        - Causes:  • PSU-EA1 defective • FU102 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               676-004
 
                        - Description:  Board Power Error-3 IOB 2: 24V_3C power off error The machine detects 24 V power off from the IOB 2.
 
                        - Causes:  • PSU-EA1 defective • FU104 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               677-001
 
                        - Description:  Board Power Error-4. PSU-EA1: 24V_ch4 power off error The machine detects 24 V power off from the PSU-EA1.
 
                        - Causes:  • Harness broken or disconnected • PSU-EA1 defective
 - Remedy:  1. Check or replace the harness. 2. Replace the PSU-EA1.
                     
                                        
                        - Code:                                                                                                                                                                                                                                                                                                               677-002
 
                        - Description:  Board Power Error-4. IOB 1: 24V_3A power off error The machine detects 24 V power off from the IOB 1.
 
                        - Causes:  • PSU-EA2 defective • FU106 on the IOB 1 shorted or opened
 - Remedy:  1. Replace the IOB 1. 2. Check or replace the PSU-EA2.