Description: Monitor Error This is a file detection and electronic file signature check error when the boot loader attempts to read the self-diagnostic module, system kernel, or root system files from the OS Flash ROM, or the items on the SD card in the controller slot are false or corrupted.
Causes: • OS Flash ROM data defective; change the controller firmware • SD card data defective; use another SD card
Description: Fatal kernel error Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.
Causes: • System program defective • Controller board defective • Optional board defective • Replace controller firmware
Remedy: 0x5032 HAIC-P2 error 0x5245 Link-up fail 0x5355 L2 Status Time Out 0x696e gwinit died 0x766d Vm_pageout: VM is full 554C USB loader defect Other
Description: Self-diagnostic Error: CPU 0008 Self-diagnostic Error: CPU: System Call Exception 0612 Self-diagnostic Error: CPU: ASIC Interrupt Error
Causes: • System program defective • Controller board defective • Optional board defective • Replace controller firmware Note: For more details about this SC code error, execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel
Description: Self-diagnostic error: ASIC The Write & Verify check of the ASIC returned an error. Note: The main ASIC module on the controller board controls the bus of the ROM device.
Causes: 3003 Check performed when HDD is installed: • HDD device busy for over 31 s. • After a diagnostic command is set for Sthe HDD, but the device remains busy for over 6 s. A diagnostic command is issued to the HDD device but the result is an error • HDD defective • HDD harness disconnected, defective • Controller board defective 3004 No response to the selfdiagnostic command from the ASIC to the HDDs • HDD defective 3013 Mandolin does not respond, the HDD device remains BUSY for more than 31 s, or the BUSY signal does not drop within 6 s after the diagnostic command is issued to the HDDs. • HDD defective • HDD connector loose or defective • Controller defective 3014 Error returned from HDD in response to the self-diagnostic command, Mandolin could not be located due to a read/write error at the HDD register. • HDD defective
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.