Description: Used toner bottle set error
The set sensor of the used toner bottle remains LOW for more than 500 ms. (The sensor goes HIGH when the bottle is installed correctly.)
Causes: • Used toner bottle not installed • Remove used toner bottle and reinstall correctly
Description: MUSIC sensor error
The MUSIC sensor detected an abnormal pattern on the ITB because: • ADC exceeded upper or lower limit. • The pattern used to calculate the amount of skew is abnormal. • The reading of the pattern exceeded the length of time the LED projected light. • LED light could not be adjusted correctly.
Causes: • ITB installed incorrectly • Inspect ITB belt for damage, replace • MUSIC pattern abnormal; do a forced process control (SP3821) and check the result. • MUSIC sensor defective or disconnected
Description: Temperature and humidity sensor error: M PCU
The thermistor output of the temperature and humidity sensor above the M PCU was not within the prescribed range (0.5V to 4.2V)
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
Description: Temperature and humidity sensor error: Toner Bottle
The thermistor output of the temperature and humidity sensor below the used toner bottle was not within the prescribed range (0.5V to 4.2V)
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.