Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D082 MPC7501 V-C3 — Trang 28/44

Code: SC572

Description: Ozone exhaust fan (K) error
The fan of the lower ozone filter box not operating correctly.
Causes: • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective

Code: SC573

Description: Ozone intake fan error
The ozone filter intake fan not operating correctly.
Causes: • Fan harness loose, broken, defective • Fan overload due to physical obstruction • Fan motor defective

Code: SC574

Description: Y thermistor error The thermistor near the Y PCU has short circuited or otherwise not operating correctly.
Causes: • Harness loose, broken, defective • Thermistor defective

Code: SC585

Description: Double-feed detection sensor error
The ADC output value of the double-feed sensor LED was not within range (2 to 250).
Causes: • Sensors are covered with paper dust or other matter and require cleaning • Sensor harness connection loose, broken, defective • There is an obstruction between the emitter/receptor sensor pair. • Sensors defective

Code: SC599

Description: Tray 1 lift motor error
An error was detected in the operation of the lift motor for Tray 1 (tandem tray).
Causes: • Motor harness loose, broken, defective • Motor overload due to an obstruction • Motor defective

Code: SC620

Description: ARDF communication error
A BREAK signal occurs after the machine detects the ARDF, or a communication timeout occurs.
Causes: • ARDF disconnected • VBCU board harness disconnected, defective • VBCU board defective • Spurious noise from the power supply line • ARDF defective

Code: SC621

Description: Mailbox-to-Finisher communication error
Communication between the mailbox and finisher is interrupted. An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed.
Causes: • Connection cable between mailbox and finisher disconnected, defective • Finisher main board defective • VBCU defective • PSU defective

Code: SC622

Description: PFB communication error
Communication between the VBCU and PFB was interrupted. (Communication status is monitored at 30 ms intervals.)
Causes: • Connection cable between the VBCU and PFB is disconnected, defective • VBCU defective • PFB defective