Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D121 MP2852 — Trang 5/22

Code: 508

Description: By-pass bottom plate error
The signal from the by-pass tray HP sensor does not change for 1.0 second after the by-pass motor has rotated counterclockwise. If this condition occurs three consecutive times, the SC is generated.
Causes: • Disconnect or defective harness of the by-pass motor • Defective or disconnected connection for the by-pass motor. • Defective by-pass motor • Disconnect or defective harness of the by-pass HP sensor • Defective or disconnected connection for the by-pass HP sensor. • Defective by-pass HP sensor
Remedy: Check the operation of the by-pass motor with SP5804-023. No operation: 1. Check the harness connection of the by-pass tray and duplex unit. 2. Replace the by-pass motor. Operation: Check the operation of the by-pass HP sensor with SP5803-048 while the by-pass motor is rotating. No change of Bit 0 1. Check the harness connection of the by-pass HP sensor. 2. Replace the by-pass HP sensor.

Code: 530

Description: Ventilation fan: front error
The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective ventilation fan: front or rear • Disconnected or defective harness • Defective DRB • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the ventilation fan: front (SC530) or rear (SC531). 3. Replace the DRB. 4. Replace the BCU.

Code: 531

Description: Ventilation fan: rear error
The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective ventilation fan: front or rear • Disconnected or defective harness • Defective DRB • Defective BCU
Remedy: 1. Check or replace the harness. 2. Replace the ventilation fan: front (SC530) or rear (SC531). 3. Replace the DRB. 4. Replace the BCU.

Code: 532

Description: Laser unit fan error
The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: • Defective laser unit fan • Disconnected or defective harness • Defective drive board • Defective BCU
Remedy: 1. Replace the laser unit fan. 2. Check the harness of the laser unit fan. 3. Replace the harness of the laser unit fan. 4. Replace the drive board. 5. Replace the BCU.

Code: 541

Description: Fusing thermistor open (center)
The temperature of the hot roller remained below 0C for 5 sec at the center of the hot roller.
Causes: • Fusing thermistor out of its position because of incorrect installation • Fusing thermistor disconnected or defective • Power supply not within rated range (15% or more below rating)
Remedy: 1. Check the fusing thermistor is set correctly. 2. Replace the fusing thermistor. 3. Check the power supply source.

Code: 542

Description: Fusing temperature warm-up error (center)
• The fusing temperature did not reach the standby temperature within 20 sec. at the center of the hot roller after the main switch turned on.
Causes: • Fusing thermistor defective or out of position • Fusing lamp disconnected • Thermistor defective • Fusing lamp defective
Remedy: 1. Check the fusing thermistor is set correctly. 2. Replace the fusing thermistor. 3. Check the fusing lamp is connected. 4. Replace the fusing lamp.

Code: 543

Description: Fusing overheat error 1 (center)
The fusing thermistor detected a fusing temperature over 230°C for 5 sec. at the center of the hot roller.
Causes: • TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective
Remedy: 1. Replace the PSU. 2. Replace the BCU board. 3. Replace the thermistor.

Code: 544

Description: Fusing overheat error 2 (center)
A fusing temperature over 250°C is detected at the center of the hot roller by the fusing temperature monitor circuit in the BCU board. The power was interrupted for more than 0.3 sec.
Causes: • TRIAC short on PSU (PSU defective) • BCU board defective • Fusing thermistor defective • Power supply voltage unstable
Remedy: 1. Replace the PSU. 2. Replace the BCU board. 3. Replace the thermistor. 4. Check the power supply source.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie