Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D121 MP2852 — Trang 21/22

Code: 921

Description: Printer error 2
When the application started, the necessary font was not on the SD card.
Causes: • A necessary font is not found in the SD card. • The SD card data is corrupted.
Remedy: Check that the SD card has the correct data.

Code: 925

Description: Network File Error
The file that manages NetFile is corrupted and operation cannot continue.
Causes: • Software defective • Files on the HDD corrupted
Remedy: 1. Do SP5-832 to format the HDD. 2. Replace the HDD.

Code: 990

Description: Software performance error
The software attempted to perform an unexpected operation due to: 1) software bug, 2) incorrect internal parameter, 3) insufficient working memory.
Causes: • Defective software • Defective controller • Software error
Remedy: • Turn the machine power off/on • Reinstall the controller and/or main firmware Note: When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP7-403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.

Code: 991

Description: Software continuity error
The software attempted to perform an unexpected operation. However, unlike SC990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect, insufficient working memory.
Remedy: This SC is not displayed on the LCD (logging only).

Code: 992

Description: Unexpected Software Error
Software encountered an unexpected operation not defined under any SC code.
Causes: • Software defective • An error undetectable by any other SC code occurred
Remedy: Print the "Logging Data" with SP5990-004 and then check the SP7990. If 498-Engine is found in the SP7990; 1. Check the harness connection of the temperature/humidity sensor. 2. Replace the temperature/humidity sensor.

Code: 994

Description: OCS record limitation error
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there if there are too many application screens open on the operation panel.
Causes: • No action required because this SC does not interfere with operation of the machine.
Remedy: • No action required because this SC does not interfere with operation of the machine.

Code: 995

Description: Controller Board Mismatch
Causes: • Defective BCU • NVRAM Replacement error
Remedy: -001 • Defective BCU • NVRAM Replacement error 1. Install the previous NVRAM. 2. Input the serial number with SP5811-004, and turn the main power switch off/on. IMPORTANT: When the BCU is replaced with a new one, this SC will occur. Therefore, make sure to do Step #2 above. Turning the power off/on links the NVRAM with the S/N information in the BCU. -002 • Defective NVRAM • Defective controller 1. Update the controller firmware. 2. Install a new NVRAM, and turn off and on the main power switch after SC995-002 has occurred. IMPORTANT: When the NVRAM is replaced with a new one, this SC will occur. Therefore, make sure to do Step #2 above. Turning the power off/on allows the NVRAM to recognize the S/N. -003 • Incorrect type controller installed • Defective controller Replace the controller with the correct type. -004 • Incorrect model controller installed. Replace the controller with the correct model.

Code: 997

Description: Application function selection error
The application selected by the operation panel key does not start or ends abnormally.
Causes: • Software (including the software configuration) defective • An option required by the application (RAM, DIMM, board) is not installed • Nesting of the fax group addresses is too complicated
Remedy: 1. Check the devices necessary for the application program. If necessary devices have not been installed, install them. 2. Check that application programs are correctly configured. 3. For a fax operation problem, simplify the nesting of the fax group addresses. 4. Take necessary countermeasures specific to the application program. If the logs can be displayed on the operation panel, see the logs.