Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D124 MPCW2200SP — Trang 7/18

Code: SC521-02

Description: Roll Unit 1 Hardware Error DSP (Digital Signal Processing) responded with a hardware error.
Causes: •X Roll paper feed motor harness loose, broken, defective •X Encoder sensor harness or encoder wheel loose, broken, defective •X Motor defective •X MCU defective
Remedy:

Code: SC522-01

Description: Roll 2 Communication Error No response from DSP (Digital Signal Processing) that controls intermittent feed from the paper rollers.
Causes: •X Cycle the machine off/on •X Check the harness connections between the roll unit, RFDB, MCU •X MCU or RFDB defective
Remedy:

Code: SC522-02

Description: Roll 2 Hardware Error DSP (Digital Signal Processing) responded with a hardware error.
Causes: •X Roll paper feed motor harness loose, broken, defective •X Encoder sensor harness or encoder wheel loose, broken, defective •X Motor defective •X MCU defective
Remedy:

Code: SC530

Description: Intake Fan Error The fan was detected rotating at less than 100 rpm three times at 300 ms intervals.
Causes: •X Fan harness loose, broken, defective •X Fan defective •X MCU defective
Remedy:

Code: SC540

Description: Vertical HP Sensor Error Not signal from the vertical HP sensor.
Causes: •X Edge of the wheel is dirty and requires cleaning •X Edge of the vertical wheel not positioned in sensor gap •X Sensor connection loose, broken, defective •X Sensor defective
Remedy:

Code: SC571-01

Description: Head Temperature Sensor Error (Black) The head temperature sensor near the black sub tanks registered a temperature that was out of range.
Causes: •X Connection loose, broken, defective at CN138 •X After correcting the problem, cycle the machine off/on
Remedy:

Code: SC571-02

Description: Head Temperature Sensor Error (Color) The head temperature sensor near the color sub tanks registered a temperature that was out of range.
Causes: •X Connection loose, broken, defective at CN138 •X After correcting the problem, cycle the machine off/on •X Sensor defective
Remedy:

Code: SC573-01

Description: Temperature/Humidity Sensor – Temperature Error The temperature/humidity sensor registered a temperature that was out of range.
Causes: •X Connection loose, broken, defective at CN217 •X After correcting the problem, cycle the machine off/on •X Sensor defective
Remedy:
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie