Mã lỗi Ricoh D124 MPCW2200SP — Trang 9/18

Code: SC637-01

Description: Tracking information notification error. Ttracking application error
Causes: Tracking information was lost. The machine failed to give notice of the tracking information to the tracking SDK application.
Remedy: •X Cycle the machine off/on

Code: SC637-02

Description: Tracking information notification error. Management server error
Causes: The machine failed to give notice of the tracking information to the management server. Tracking information was lost, and the machine could not count correctly.
Remedy: •X Cycle the machine off/on

Code: SC640

Description: Engine-to-Controller Communication Error CTL This is a checksum error.
Causes: •X PCI hardware error
Remedy: •X Cycle the machine off/on

Code: SC641

Description: Engine serial communication error CTL An error occurs in serial communication with engine.
Causes: •X SC641-1: Timeout error •X SC641-2: Retry over •X SC641-3: Download error •X SC641-4: UART error
Remedy: •X Cycle the machine off/on

Code: SC650-01

Description: @Remote communication error (Cumin-M)
Causes: The authentication for the Cumin-M fails failed at a dial up connection due to one or more of the following: •X Incorrect SP settings •X Disconnected telephone line •X Disconnected modem board •X Disconnected wireless LAN card
Remedy: •X Check and set the correct user name (SP5-816-156) and password (SP5-816-157).

Code: SC650-04

Description: @Remote communication error (Cumin-M) Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection.
Causes: The authentication for the Cumin-M fails failed at a dial up connection due to one or more of the following: •X Incorrect SP settings •X Disconnected telephone line •X Disconnected modem board •X Disconnected wireless LAN card
Remedy: •X Check and set the correct user name (SP5-816-156) and password (SP5-816-157).

Code: SC650-05

Description: @Remote communication error (Cumin-M) No modem board Modem board is not installed even though the setting at Cumin-M (During the operation)
Causes: The authentication for the Cumin-M fails failed at a dial up connection due to one or more of the following: •X Incorrect SP settings •X Disconnected telephone line •X Disconnected modem board •X Disconnected wireless LAN card
Remedy: •X Check and set the correct user name (SP5-816-156) and password (SP5-816-157).

Code: SC650-13

Description: @Remote communication error (Cumin-M) Modem board error 1
Causes: Modem board not installed or the board is defective.
Remedy: •X Install the modem board. •X Check correct setting value for modem driver (SP5-816-160, SP5-816-165 to 171, SP5-816-188 and 189). •X Replace the modem board.