Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D132 MP7502 — Trang 32/33

Code: 984

Description: Print image data transfer error After a data transfer begins from the controller to the engine via the PCI bus, the transfer does not end within 15 s.
Causes: • Controller (SIMAC) board defective • BICU defective • BICU/controller disconnected

Code: 985

Description: Scanned image data transmission error After a data transfer begins from the engine to the controller via the PCI bus, the transfer does not end within 3 s.
Causes: • Controller (SIMAC) board defective • BICU defective • BICU/controller disconnected

Code: 986

Description: Software error 1 The write parameter received by the write module at the beginning of the setting table is NULL.
Causes: • Controller (SIMAC) board defective • BICU defective • BICU/controller disconnected

Code: 990

Description: Software Performance Error 1 An unexpected operation was encountered by the software.
Causes: • Defective software • Defective controller • Software error

Code: 991

Description: Software continuity error The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect • Insufficient working memory

Code: 992

Description: Undefined Error (No SC Code) An error not controlled by the system occurred (the error does not come under any other SC code).
Causes: • Software defective • Turn the machine power off and on. The machine cannot be used until this error is corrected. • Re-install firmware

Code: 994

Description: Operation Panel Management Records Exceeded An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there are too many application screens open on the operation panel.
Causes: No action required because this SC does not interfere with operation of the machine.

Code: 995

Description: CPM setting error
Causes: 01 • Defective BCU • NVRAM Replacement error • Install the previous NVRAM. • Input the serial number with SP5-811-004, and turn the main power switch off and on. 02 • Defective NVRAM • Defective controller • Update the controller firmware. • Install a new NVRAM, and turn off and on the main power switch after SC995-002 has occurred. 03 • Incorrect type controller installed • Defective controller • Replace the controller with the correct type. 04 • Incorrect model controller installed. • Replace the controller with the correct model.