Mã lỗi Ricoh D182 MP2553 OR-C2 — Trang 21/30

Code: SC794-10

Description: Stapler motor error. The machine does not detect a correct signal from the stapler motor HP sensor while thestapler motor is operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Staple jam • Defective stapler motor • Loosen connection • Motor overload • Defective stapler motor HP sensor
Remedy: • Remove the jammed staple. • Reset the connector • Replace the stapler motor HP sensor. • Replace the stapler motor.

Code: SC794-11

Description: Stapler unit motor error without 1-bin tray (D586) The machine does not detect a correct signal from the stapler unit motor HP sensor while the stapler unit motor is operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Defective stapler unit motor • Loosen connection • Motor overload • Defective stapler unit motor HP sensor
Remedy: • Reset the connector • Replace the stapler unit HP sensor. • Replace the stapler unit motor.

Code: SC794-12

Description: Shift roller motor error without 1-bin tray (D586) The machine does not detect a correct signal from the shift roller HP sensor while the shift roller motor is operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Defective shift roller motor • Loosen connection • Motor overload • Defective shift roller HP sensor
Remedy: • Reset the connector • Replace the shift roller HP sensor. • Replace the shift roller motor.

Code: SC816-01

Description: Subsystem error
Causes: Energy save I/O subsystem detected some abnormality. • Energy save I/O subsystem defective • Energy save I/O subsystem detected a controller board error (non-response). • Error was detected during preparation for transition to STR.
Remedy: • Turn the main power off/on. • Replace the controller board.

Code: SC816-02

Description: Sysarch (LPUX_GET_PORT_INFO) error
Causes: Energy save I/O subsystem detected some abnormality. • Energy save I/O subsystem defective • Energy save I/O subsystem detected a controller board error (non-response). • Error was detected during preparation for transition to STR.
Remedy: • Turn the main power off/on. • Replace the controller board.

Code: SC816-03

Description: Transition to STR was denied.
Causes: Energy save I/O subsystem detected some abnormality. • Energy save I/O subsystem defective • Energy save I/O subsystem detected a controller board error (non-response). • Error was detected during preparation for transition to STR.
Remedy: • Turn the main power off/on. • Replace the controller board.

Code: SC816-04

Description: Interrupt in kernel communication driver
Causes: Energy save I/O subsystem detected some abnormality. • Energy save I/O subsystem defective • Energy save I/O subsystem detected a controller board error (non-response). • Error was detected during preparation for transition to STR.
Remedy: • Turn the main power off/on. • Replace the controller board.

Code: SC816-05

Description: Preparation for transition to STR failed.
Causes: Energy save I/O subsystem detected some abnormality. • Energy save I/O subsystem defective • Energy save I/O subsystem detected a controller board error (non-response). • Error was detected during preparation for transition to STR.
Remedy: • Turn the main power off/on. • Replace the controller board.