Các lỗi thường gặp

Code :
  • Code: 367
  • Description: TD sensor (Vt low) error 2: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector disconnected, loose, defective • TD sensor defective
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.
  • Code: 372
  • Description: TD sensor adjustment error: K
    During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.
  • Code: 373
  • Description: TD sensor adjustment error: M
    During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.
  • Code: 374
  • Description: TD sensor adjustment error: C
    During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.
  • Code: 375
  • Description: TD sensor adjustment error: Y
    During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.
  • Code: 380
  • Description: Drum gear position sensor error: K
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCU.
  • Code: 381
  • Description: Drum gear position sensor error: M
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCU.
  • Code: 382
  • Description: Drum gear position sensor error: C
    The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCU.