Các lỗi thường gặp

Code :
  • Code: 240
  • Description: LD error
    The IPU detected a problem at the LD unit.
  • Causes: Defective LD unit. Disconnect harness. Disconnect LD Driver.
  • Remedy: • Connect the harness properly. • Replace the LD unit.
  • Code: 312
  • Description: Charge roller current leak
    The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.fective BCU.
  • Causes: Cartridge (charge roller) defective. High voltage supply board defective. Disconnect harness.
  • Remedy: • Turn the Power Switch Off and On. • Connect the harness properly. • Replace the AIO unit. • Replace the High voltage power supply board.
  • Code: 320
  • Description: Development Bias leak
    The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.
  • Causes: Bias applying section leak. High voltage supply board defective. Disconnect harness. Development Bias CN loose
  • Remedy: • Connect the harnesses properly. • Replace the AIO. • Replace High voltage power supply board.
  • Code: 440
  • Description: Primary Transfer PP output leak
    The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.
  • Causes: High voltage supply board defective. Disconnect harness. Development Bias CN loose
  • Remedy: • Connect the harnesses properly. • Replace the AIO. • Replace High voltage power supply board.
  • Code: 500
  • Description: Main motor lock
    The machine does not detect a main motor lock signal within 1 second after the main motor starts to rotate. -or- The machine does not detect a main motor lock signal for 250 ms continuously while the main motor is rotating.
  • Causes: Mechanical overload on the drive mechanism. Main motor defectivess.
  • Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the main motor.
  • Code: 530
  • Description: Exhaust fan motor error
    The CPU detects an exhaust fan lock signal for more than 2 seconds.
  • Causes: Mechanical overload on the Exhaust fan mechanism. Exhaust fan harness loose or broken
  • Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the Exhaust fan.
  • Code: 531
  • Description: Reverse Fan Motor error
    The CPU detects a Reverse fan lock signal for more than 2 seconds.и#0
  • Causes: Mechanical overload on the Reverse fan mechanism. Reverse fan harness loose or broken
  • Remedy: • Remove foreign materials from the reverse fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the reverse fan.
  • Code: 532
  • Description: PSU Fan Motor error
    The CPU detects a PSU fan lock signal for more than 2 seconds.
  • Causes: Mechanical overload on the PSU fan mechanism. PSU fan harness loose or broken
  • Remedy: • Remove foreign materials from the PSU fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the PSU fan.