Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh M158 SP4510DN Gim-P1c

Code: SC101

Description: Exposure Lamp Error
Causes: The scanner has scanned the white plate, but cannot detect the certain white level. • Defective exposure lamp • Defective exposure lamp stabilizer • Defective power source harness • Defective signal harness • High-voltage cable leak • Defective darkness starting characteristic
Remedy: Turn the main power OFF and then ON.

Code: SC120

Description: Scanner home position error 1
Causes: The scanner home position sensor does not detect the scanner leaving the home position. • Defective scanner home position sensor • Defective scanner home position sensor harness • Defective scanner motor driver • Defective scanner motor
Remedy: Turn the main power OFF and then ON.

Code: SC121

Description: Scanner home position error 2
Causes: The scanner home position sensor does not detect the scanner coming back to the home position. • Defective scanner home position sensor • Defective scanner home position sensor harness • Defective scanner motor driver • Defective scanner motor
Remedy: Turn the main power OFF and then ON.

Code: SC141

Description: Black level correction error
Causes: The automatic adjustment has failed to correct the black level to the permissible range. • Defective SBU board • Defective harness
Remedy: Turn the main power OFF and then ON.

Code: SC142

Description: White level correction error
Causes: The automatic adjustment has failed to correct the white level to the permissible range. • Defective scanner drive • Defective optical section • Defective SBU board • Defective harness
Remedy: Turn the main power OFF and then ON.

Code: SC144

Description: SBU Communication Error
Causes: Cannot correctly establish communication with the SBU. • Defective harness • Defective destination device (e.g., BICU, etc) • Defective SBU
Remedy: Reboot the machine.

Code: SC161-01

Description: IPU error (LSYNC error)
Causes: When turning the power on or when recovering from energy saving mode, the machine performs a BICU self-diagnostic test. If it detects an error, it reports an IPU (LSUNC) error. • Defective IPU or BICU (or bad connection between the ASIC and the LEO, LSYNC Abnormal, etc) • Faulty cable connection between the SBU and IPU (or BICU).
Remedy: • Check the connection between SBU and IPU (BICU) • Replace the IPU (BICU)

Code: SC161-02

Description: IPU error (RI response error)
Causes: Detecting an error on access to the RI. Defective IPU (BICU, ICTL) or RI abnormal performance, etc