Code: 545

Description: Fusing lamp overheat error (center)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 12 consecutive seconds.
Causes: • Fusing thermistor defective or out of position • Power supply board defective

Code: 546

Description: Unstable fusing temperature (center)
The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times.
Causes: • Thermistor defective or out of position • Power supply unit defective

Code: 547

Description: Zero cross signal malfunction
The relay terminal of the fusing unit is melted, zero cross signals are not detected within 3 seconds after the main power switch is turned on, or detected zero cross signals are 44 times or less.
Causes: • Discharge plate defective • High-voltage supply board defective • BICU defective

Code: 551

Description: Fusing thermistor open (rear)
The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on.
Causes: • Fusing thermistor defective or out of position • Power supply board defective • Loose connectors

Code: 552

Description: Fusing temperature warm-up error (rear)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
Causes: • Fusing thermistor defective or out of position • Fusing lamp open • Power supply board defective

Code: 553

Description: Fusing overheat error (rear)
The fusing temperature is over 230°C for 1 second (detected by the thermistor).
Causes: • Fusing thermistor defective • Power supply board defective

Code: 555

Description: Fusing lamp overheat error (rear)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 20 consecutive seconds.
Causes: • Fusing thermistor defective or out of position • Power supply board defective

Code: 556

Description: Unstable fusing temperature (rear)
The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times.
Causes: • Thermistor defective or out of position • Power supply unit defective