Description: Belt platen operation error The vacuum positioning sensor fails to deactivate when the belt platen operates.
Code: 245 S98
Description: Error in Image Adjustment Paper size used in Image Adjustment is out of the range. Or the scanned data by the CCD is wrong (out of the range).
Code: 246 S96
Description: Wire not connected to suction fan No.5.
Code: 247 S96
Description: Wire not connected to suction fan No.6.
Code: 248 S03
Description: BP spacer movement error 1 The BP spacer HP sensor is OFF when the BP spacer should have moved to HP position.
Code: 249 S03
Description: BP spacer movement error 2 The BP spacer HP sensor is ON when the BP spacer should have moved out of HP position.
Code: 250 S03
Description: BP spacer movement error 3 When the BP spacer should have moved to the NORMAL paper position (moved to the left), the limit sensor does not go ON.
Code: 251 S03
Description: BP spacer movement error 4 When the BP spacer should have moved out from the NORMAL paper position towards the HP position (moved to the right), the limit sensor does not go OFF.