Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Riso HC5500 — Trang 21/46

Code: 312 S05

Description: Head abnormally hot The head temperature exceeded 80 °C. When the reading of the thermistor is 80.0 °C * Head identification information (K1 - Y6) is added after the error point.

Code: 313 S05

Description: Head cooling timeout The temperature remained above 45 °C for 10 minutes. When the monitored head temperature remains 45 °C or more for 10 minutes * Head identification information (K1 - Y6) is added after the error point.

Code: 314 S06

Description: Ink heating timeout When the temperature of ink in the distributor meets the following conditions after being heated for a set time: 1) & either 2), 3) 4), 5), 6) or 7) 1) The temperature is less than 15 °C. 2) It takes more than 360 seconds to raise the temperature by 1 °C after the heater has been powered on. 3) It takes more than 600 seconds to raise the temperature by 4 °C after the heater has been powered on. 4) It takes more than 750 seconds to raise the temperature by 7 °C after the heater has been powered on. 5) It takes more than 900 seconds to raise the temperature by 10 °C after the heater has been powered on. 6) It takes more than 1,320 seconds to raise the temperature by 13 °C after the heater has been powered on. 7) A temperature of less than 15 °C holds for more than 1,800 seconds. * Head identification information (K, C, M, Y) is added after the error point.

Code: 315 W99

Description: ID unit low liquid level Low liquid level is detected in the ID unit of each color ink. * Ink identification information (K, C, M, Y) is added after the error point.

Code: 316 S96

Description: Reservoir not connected * Ink identification information (K, C, M, Y) is added after the error point.

Code: 317 S96

Description: ID unit air open valve not connected * Ink identification information (K, C, M, Y) is added after the error point.

Code: 318 S96

Description: Distributor unit not connected * Unit identification information (KC, MY) is added after the error point.

Code: 319 S07

Description: Ink cooling timeout The temperature of ink being distributed remains 40 °C for five minutes. * Ink identification information (K, C, M, Y) is added after the error point.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie