Description: Error on Finisher resumption information Since there is the error on Finisher resumption information from HC control PCB, IP can not restart printing.
Code: 064 S98
Description: Incorrect controller version HC5500 is equipped with the controller for HC5000.
Code: 065 S98
Description: Incorrect NVRAMI P PCB is equipped with the NVRAM for HC5000
Code: 0xx
Description: System (power supply, H/W, S/W, communication), panel
Code: 100 S12
Description: Exit motor encoder error The encoder frequency input from the exit motor unit deviates from the theoretical value.
Code: 101 S98
Description: Multiple feed sensor error A change in light intensity does not change the amount of light received at power ON or during initialization to reset a multiple feed error. * This error can be cleared by the panel setting [Multiple feed detection OFF].
Code: 102 S12
Description: Wing motor timeout The wings do not reach the HP when they are operated for a period of time corresponding to the distance of travel.
Code: 103 S12
Description: Wing motor timeout The wing HP sensor does not detect the movement of the wings from the HP when they are operated for the specified interval.