Description: Belt encoder error The frequency input from the belt encoder is below the specified value.
Code: 205 S96
Description: Blower fan 1 disconnected/not connected The connector for blower fan 1 is disconnected, or there is a break in the winding.
Code: 206 S96
Description: Blower fan 2 disconnected/not connected The connector for blower fan 2 is disconnected, or there is a break in the winding.
Code: 207 S96
Description: Blower fan 3 disconnected/not connected The connector for blower fan 3 is disconnected, or there is a break in the winding.
Code: 208 S96
Description: Blower fan 4 disconnected/not connected The connector for blower fan 4 is disconnected, or there is a break in the winding.
Code: 209 X07
Description: Duplex re-feed unit failure The registration sensor fails to activate when the specified number of clock inputs is issued from the belt encoder after paper is re-fed for duplex printing.
Code: 210 X02
Description: Registration sensor paper end exiting delay The trailing edge of the paper sheet does not pass the registration sensor within the specified interval based on the belt encoder pulse count.
Code: 211 X02
Description: Top edge sensor paper leading edge arrival delay The leading edge of the paper sheet does not reach the top edge sensor (sensor does not detect the presence of paper) within the specified interval based on the belt encoder pulse count.