Description: EEPROM version error. Error in writing into EEPROM.
Causes: EEPROM defective Uninitialized EEPROM is installed Defective EEPROM access circuit on PCU PWB
Remedy: Check EEPROM for proper set-up To prevent the erasion of counter data and adjustment values, write down the counter data and adjustment values by simulation. (If there is a printer option, execute SIM23-1 and note counter data/adjustment values.) Clear U2 trouble with SIM16. Replace PCU PWB.
Causes: EEPROM defective Control circuit hung up due to noise Defective EEPROM access circuit on PCU PWB
Remedy: Check EEPROM for proper set-up To prevent the erasion of counter data and adjustment values, write down the counter data and adjustment values by simulation. (If there is a printer option, execute SIM23-1 and note counter data/adjustment values.) Clear U2 trouble with SIM16. Replace PCU PWB.
Description: Checksum error in adjustment value data area
Causes: EEPROM defective Control circuit hung up due to noise. Defective EEPROM access circuit on PCU PWB
Remedy: Check EEPROM for proper set-up To prevent the erasion of counter data and adjustment values, write down the counter data and adjustment values by simulation. (If there is a printer option, execute SIM23-1 and note counter data/adjustment values.) Clear U2 trouble with SIM16. Replace PCU PWB.
Description: Mirror motor power supply error. Mirror motor power supply voltage judged to be improper when mirror initial or mirror field is started.
Causes: Mirror motor PWB defective Mirror motor power supply circuit defective DC power supply defective Improper connection of harness for supplying mirror motor DC38V
Remedy: Check mirror motor power supply with SIM1-2. Check harness and connection for supplying mirror motor DC38V.
Description: ADU alignment plate operation error. The plate won’t move from home position more than 1 second after sending the command to leave home position. Or the plate won’t return to home position within 5 seconds after sending the command to return to home position.
Causes: Home position sensor defective Alignment shift motor defective Improper connection of harness between PCU PWB, motor and sensor. Control PWB (PCU) defective Alignment plate driving belt or gear damaged or improperly adjusted
Remedy: Check home position sensor detection with SIM9-2. Check alignment plate operation with SIM9-4. Check connection between PCU, motor and sensor. Remove ADU and check gear and belt for damage.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.