Description: Too hot fusing section. The fusing temperature is over 241.5#C (less than 1.3-V input voltage is detected.)
Causes: Thermister defective Control PWB defective Improper connection of fusing unit connector AC power supply defective
Remedy: Check heater lamp operation with SIM5-2. If lamp blinks properly: Check thermister and its harness. Check thermister input circuit of control PWB. If lamp lights and stays lit: Check lamp control circuits of AC PWB and control PWB. Clear the trouble with SIM14.
Description: Too cold fusing section Detail The temperature does not reach the preset value within the specified time (3 min. in usual modes; 5 min. in curl correction mode.) after the power relay is turned on.
Causes: Thermister defective Heater lamp defective Control PWB defective Thermostat defective AC power supply defective Interlock switch defective
Remedy: Check heater lamp for blinking with SIM5-2. If lamp blinks properly: Check thermister and its harness. Check thermister input circuit of control PWB. If lamp does not light: Check heater lamp for broken wire and thermostat for operation. Check interlock switch. Check lamp control circuit of AC PWB and control PWB. Clear the trouble with SIM14.
Description: Scanner field trouble No TRC or RRC output trouble. Scanner field is not finished within 10 seconds. TRC or RRC output is not produced within 5 seconds after the start of scanner field.
Causes: Mirror unit defective Scanner wire disconnected
Description: Drum motor lock detected. Motor lock signal is detected for 1.5 seconds during drum motor rotation.
Causes: Drum motor defective Improper connection of harness between PCU PWB and drum motor Control circuit defective
Remedy: Check drum motor operation with SIM25-1. Check harness and connector between PCU PWB and drum Check polygon motor operation with SIM61-1. Check harness and connector for connection. Replace LSU if needed.motor.
Description: Polygon motor lock detected. It was judged that there is no output of polygon motor lock signal of LSU. The lock signal was checked at about 10-second intervals after the polygon motor started rotating. As result, it was judged that the polygon motor failed to operate normally.
Causes: Disconnected connecter to LSU or detached harness inside LSU or broken wire. Polygon motor defective
Remedy: Check polygon motor operation with SIM61-1. Check harness and connector for connection. Replace LSU if needed.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.