Description: Half-tone process control 1st batch trouble (Magenta)
Causes: First step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Description: Half-tone process control 1st batch trouble (Yellow)
Causes: First step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Description: Half-tone process control 2nd batch trouble (Black)
Causes: Second step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Description: Half-tone process control 2nd batch trouble (Cyan)
Causes: Second step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Description: Half-tone process control 2nd batch trouble (Magenta)
Causes: Second step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Description: Half-tone process control 2nd batch trouble (Yellow)
Causes: Second step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Causes: The difference between the correction value after execution of half-tone process control and the previous correction value exceeds the specified max. value of each color. <The error is recorded in the trouble history, but F2 trouble is not indicated on the display and the previous correction value is remained.>
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Causes: LUD1 does not turn on within the specified time.
Remedy: Case 1 Cause LUD1 sensor trouble, disconnection of harness among the PCU PWB, the lift-up unit, and the paper feed unit. Check & Remedy Check LUD1, its harness, and the connector. Case 2 Cause Cassette 1 lift-up motor trouble Check & Remedy Check the lift-up unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.