Description: ICU-PRT communication trouble (ICU detection)
Causes: Communication establishment error, framing, parity, protocol error
Remedy: Case 1 Cause Defective connection of the ICU/PRT PWB communication connector, defective harness between the ICU PWB and the PRT PWB, defective ICU PWB/ PRT PWB Check & Remedy Check connection and the harness between the ICU PWB and the MFP PWB. Check the machine earth. Replace the ICU or the PRT PWB.
Causes: The HDD (option) does not operate normally in the machine with the HDD.
Remedy: Case 1 Cause Defective connection of the HDD connector, defective HDD, defective PRT PWB Check & Remedy Check the HDD again. Replace the HDD. Replace the PRT PWB.
Remedy: Case 1 Cause Disconnection of the fusing section connector Check & Remedy Check the connector and the harness between the thermistor and the control PWB. Case 2 Cause The fusing unit is not installed. Check & Remedy Install the fusing unit. Case 3 Cause Thermistor trouble, control PWB trouble, AC power supply trouble Check & Remedy Replace the thermistor or the control PWB. Check the AC power supply.
Remedy: Case 1 Cause Disconnection of the fusing section connector Check & Remedy Check the connector and the harness between the thermistor and the control PWB. Case 2 Cause The fusing unit is not installed. Check & Remedy Install the fusing unit. Case 3 Cause Thermistor trouble, control PWB trouble, AC power supply trouble Check & Remedy Replace the thermistor or the control PWB. Check the AC power supply.
Description: Fusing section high temperature trouble (THS1)
Causes: The fusing temperature exceeds 230°C.
Remedy: Common Check Use SIM 5-2 to check the heater lamp flashing operation. Case 1 Cause The heater lamp flashes properly with SIM 5-2. Thermistor trouble, disconnection of the fusing section connector Check & Remedy Check the thermistor and its harness. Cancel the error with SIM 14. Case 2 Cause The heater lamp keeps ON with SIM 5-2. Control PWB trouble, AC power supply trouble Check & Remedy Check the AC PWB and the control PWB lamp control circuit. Cancel the error with SIM 14.
Description: Fusing section high temperature trouble (THS2)
Causes: The fusing temperature exceeds 230°C.
Remedy: Common Check Use SIM 5-2 to check the heater lamp flashing operation. Case 1 Cause The heater lamp flashes properly with SIM 5-2. Thermistor trouble, disconnection of the fusing section connector Check & Remedy Check the thermistor and its harness. Cancel the error with SIM 14. Case 2 Cause The heater lamp keeps ON with SIM 5-2. AC power supply trouble, control PWB trouble Check & Remedy Check the AC PWB and the control PWB lamp control circuit. Cancel the error with SIM 14.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.