Mã lỗi Sharp ARC265P — Trang 5/10
Display: Service Call 122: Error
Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
Causes: 1) Is fan in low-voltage power supply unit operating? 2) Error reoccurs after replacing fan motor.
Display: Service Call 123: Error
Description: Improper environment humidity detected by sensor.
Causes: 1) Is error message displayed? 2) Does error reoccur?
Display: Service Call 124: Error
Description: Improper environment temperature detected by sensor.
Causes: 1) Is error message displayed? 2) Does error reoccur?
Display: Service Call 125: Error
Description: Error detected at MT home position.
Causes: 1) Is error message displayed? 2) Does error reoccur?
Display: Turn power OFF and wait 126: Dew error
Description: Sensor dew error.
Causes: Sensor dew error detected.
Display: Service Call 130: Error
Description: Temperature rise detected at LED head.
Causes: 1) Is error message displayed? 2) Does error reoccur?
Display: Service Call 131: Y Head 132: M Head 133: C Head 134: K Head
Description: Same unit not detected upon power ON or opening cover.
Causes: 1) Is error message displayed? 2) Is LED head properly set? 3) Does error reoccur?
Display: Service Call 140: Y ID 141: M ID 142: C ID 143: K ID
Description: Error detected at proper ID position.
Causes: 1) Is error message displayed? 2) Does error reoccur?